OnC FlowSens

OnC FlowSens

High level of measurement accuracy and extensive self diagnostics

The accurate OnC FlowSens flow meter is suitable for all flow measurements for paper manufacturing, including water, stock, steam, chemicals and auxiliary materials.

With OnC FlowSens, the measurement accuracy is better than 0.15%. The nominal diameter of the magnetic-inductive flow meter (FS 604) ranges from DN 2.5 to DN 2000, and that of the magnetic-inductive ceramic flow meter (FS 605) from DN 2.5 to DN 25. Air bubbles in the medium are compensated for in equal measure by both sensors. Sensors are available in both versions with directly fitted transducer (compact version) or separate transducer. Likewise there are optional low-noise electrodes for both OnC FlowSens variants. The ceramic sensor is also suitable for severely abrasive media. For both devices, a transducer (UC 600) is available as a compact version, wall enclosure or field enclosure.

Measurements of various media are possible with the OnC FlowSens flow sensor. It offers a high level of measurement accuracy and extensive self diagnostics.

Model overview OnC FlowSens 

OnC FlowSens 601

OnC FlowSens 601

FS601

 

  •  Diameter range DN10–DN150
  •  Wafer design
  •  Liner, PFA
  •  Electrode material Hastelloy
  •  Accuracy 0.3% with OnC UniCom


Application:
Covering volumetric flow applications in pulp, paper and water treatment with a minimum conductivity > 20 ±S/cm

OnC FlowSens 602 

OnC FlowSens 602

FS602

 

  • Diameter range: DN25–DN3000 with flanges
  • Various liner options available: DN25–DN150 polypropylene, DN200–DN3000 ebonite hard rubber
  • Various electrode materials available
  • Accuracy 0.3% with OnC UniCom 601

Application:
For water, wastewater and sludge applications

OnC FlowSens 604

OnC FlowSens 604

FS604

 

  • Diameter range: DN2.5–DN3000 with flanges
  •  Various liner options available, e.g. PTFE, PFA, ETFE
  •  Reinforced liner with stainless steel wire
  •  Various electrode materials available
  •  Accuracy 0.2% with OnC UniCom 600


Application:
Covering volumetric flow applications in pulp, paper and water treatment with a minimum conductivity > 20 ±S/cm

OnC FlowSens 605

OnC FlowSens 605 ceramic liner

FS605
Flow tube with ceramic liner for high end applications that is specifically designed for abrasive media.

 

  •  Diameter range DN2.5–DN300 with
    flanges
  •  Various electrode materials available
  •  Accuracy 0.2% with OnC UniCom 600
  •  Also available in wafer design DN2.5-
    DN100


Application:

  •  After MC pump at high consistencies
  • Filler dosing
  •  Chemical dosing
  •  Coating colors

OnC UniCom 600 Wall-mount version

Signal converter for FS601/602/604/605

UC600
UC600W is a wall-mount version with a polycarbonate housing.

UC600C offers a compact design, for mounting on a flow sensor.

UC600F is a field-mount version with a die-cast aluminum housing.

 

  • 3x100% diagnostics of application, accuracy and instrument
  • Large graphic display with piezoelectric buttons
  • Quick and easy installation and start-up
  • Excellent long-term stability
  • Optimal zero point stability independent from product properties OnC UniCom 600 Wall-Mount version
  • Integrated temperature and conductivity measurement
  • Indication of erroneous measurement, e.g. because of gas bubbles
  • Display of accuracy and linearity errors
  • Output 4–20 mA HART, pulse, frequency or status output, limit switch or control Input depending on the I/O version
  • Options Profibus PA and DP
  • Internal counters with a maximum of 8 counter places e.g. for counting volume or mass units

Application:
Conductive liquid media containing

  • solids < 70% (vol)
  • gas > 5% (vol)
  • fibers > 30% (vol)

OnC UniCom 600 Field-mount version

Signal converter for FS601/602/604/605

UC600
UC600W is a wall-mount version with a polycarbonate housing.

UC600C offers a compact design, for mounting on a flow sensor.

UC600F is a field-mount version with a die-cast aluminum housing.

  •  3x100% diagnostics of application, accuracy and instrument
  •  Large graphic display with piezoelectric buttons
  •  Quick and easy installation and start-up
  •  Excellent long-term stability
  •  Optimal zero point stability independent from product properties OnC UniCom 600 Wall-mount version
  •  Integrated temperature and conductivity measurement
  •  Indication of erroneous measurement, e.g. because of gas bubbles
  •  Display of accuracy and linearity errors
  •  Output 4–20 mA HART, pulse, frequency or status output, limit switch or control Input depending on the I/O version
  •  Options Profibus PA and DP
  •  Internal counters with a maximum of 8 counter places e.g. for counting volume or mass units

Application:
Conductive liquid media containing

  • solids < 70% (vol)
  • gas > 5% (vol)
  • fibers > 30% (vol)

OnC UniCom 601 signal converter

Signal converter for FS601/602/604/605

UC601
UC601W is a wall mount version with a die-cast aluminum housing. UC 601C offers compact design, is mounted on the flow sensor and has a die-cast aluminium housing

 

  • Large graphic display with push buttons
  • Quick and easy installation and start-up
  • Excellent price-performance ratio
  • Integrated temperature and conductivity measurement
  • Diagnostic tools for device function and application check
  • Output 4–20 mA HART, pulse, frequency, status output or limit switch
  • Internal counters with a max. of 8 counter places e.g. for counting volume or mass units

Application:
Conductive liquid media containing

  • solids < 10% (vol)
  • gas > 3% (vol)
  • fibers > 0,5% (vol)

OnC FlowSens Vortex 610 

OnC FlowSens 610 Vortex

FS610
Unique 2-wire flowmeter with integrated temperature compensation.

 

  • Process connections flange DN15–DN300 or sandwich DN15–DN100
  • 2-wire flowmeter 4–20 mA HART
  • Temperature compensation for saturated steam
  • Optional with integrated pressure compensation
  • Excellent long-time stability due to wearless stainless steel construction
  • Welded bluff body, eliminates mechanical movement
  • No risk of deposits, no damage from solid particles
  • Also available in splitted version

Applications:
Steam, gas and non conductive liquids < 10 cP